Small Anechoic Room for Loudspeaker, Microphone & Component Testing

紧凑型消声室

Compact and small anechoic chambers designed for loudspeaker characterisation, microphone calibration, earphone and headphone testing, hearing aid measurement, and small electronic component acoustic evaluation. Available from tabletop enclosures (0.5 m³) to walk-in rooms (30 m³), with cut-off frequencies from 200 Hz upward and free-field deviation ±1.5 dB.

产品图库

5 张图片 · 点击放大

技术规格

Cut-off frequency range200 Hz – 800 Hz (size-dependent)
Free-field deviation±1.5 dB above cut-off
Background noise≤ NC-15 to NC-20 (size-dependent)
Size range0.5 m³ tabletop – 200 m³ custom
Wedge materialMelamine / fiberglass / polyurethane foam
Wedge NRC≥ 0.95
ConfigurationFully anechoic or hemi-anechoic
Standard complianceISO 3745, IEC 60268-5, IEC 60318
通道Hinged door / removable panel
PowerFiltered IEC outlet (optional)
CalibrationFree-field qualification report
Lead time6–12 weeks (size-dependent)

规格仅用于初步项目评估。最终参数、材料、证书和验收标准应以签署合同或批准的技术方案为准。

应用

  • Loudspeaker driver and system characterisation (IEC 60268-5)
  • Microphone calibration and directivity measurement
  • Earphone, headphone, and in-ear monitor testing
  • Hearing aid and hearing instrument measurement
  • PA horn and column array directivity characterisation
  • MEMS microphone and transducer quality control
  • Research and university acoustics laboratories

概览

Many acoustic measurement applications require free-field conditions but do not demand the scale of a full automotive or industrial anechoic chamber. A compact anechoic chamber provides the same free-field measurement environment — just sized to the test object and measurement distance required.

HEMU Acoustics compact anechoic chambers cover four size classes:

**Tabletop Enclosure (0.5–5 m³)** — For consumer electronics, earphones, in-ear monitors, and hearing aid measurements. Interior lined with 100–150 mm wedges achieving a cut-off frequency of 500–800 Hz. Background noise ≤ NC-20. Typically used with a measurement microphone at 10–50 cm distance. Folded test windows on two sides provide access without disturbing the acoustic field.

**Benchtop Chamber (5–20 m³)** — For loudspeaker drivers, microphones, and small transducers. Wedge length 150–300 mm, cut-off frequency 200–400 Hz. Background noise ≤ NC-15. Interior height 1.2–1.8 m. Test object suspended on wire frame to minimise reflections.

**Walk-In Chamber (20–50 m³)** — For loudspeaker systems, public address (PA) horns, and directional microphone arrays. Wedge length 300–500 mm, cut-off frequency 150–200 Hz. Background noise ≤ NC-15. Sufficient test distance (1–2 m) for far-field loudspeaker measurement per IEC 60268-5.

**Custom Laboratory Chamber (50–200 m³)** — For array antenna measurement, directivity characterisation, and precision calibration. Wedge length up to 800 mm, cut-off frequency 100 Hz. Full ISO 3745 qualification achievable.

All sizes are available as fully anechoic (6 anechoic surfaces) or hemi-anechoic (5 anechoic + 1 reflective floor) configurations.

核心特性

±1.5 dB Free-Field Condition (200 Hz Upward)

Free-field condition verified to ±1.5 dB (ISO 3745 criterion) above the chamber cut-off frequency. For walk-in chambers (300 mm wedges), cut-off is typically 200–250 Hz. For tabletop enclosures (100–150 mm wedges), cut-off is 500–800 Hz. All chambers are acoustically qualified and supplied with a free-field deviation measurement report.

Four Size Classes — Tabletop to Walk-In

Tabletop (0.5–5 m³) for earphones and microphones; benchtop (5–20 m³) for drivers and transducers; walk-in (20–50 m³) for loudspeaker systems; custom laboratory (50–200 m³) for array and directivity work. All classes share the same wedge system and panel construction principles — different only in scale.

Melamine Foam Wedges (≥ 0.95 NRC)

Standard wedge material is open-cell melamine foam — lightweight (10 kg/m³), self-supporting, fire-rated (B1/B2 class), and achieving NRC ≥ 0.95 from cut-off frequency upward. Fiberglass wedges are available for higher mechanical durability. Custom wedge profiles (pyramids, flat absorber tiles) available for very small enclosures.

≤ NC-15 Background Noise

Mass-law isolation achieved through 50–100 mm steel panel walls (small enclosures) or composite concrete/steel construction (walk-in rooms). All chambers are placed on anti-vibration pads or spring isolators depending on host environment. Mechanical service penetrations use acoustic gland fittings. Target background noise NC-15 to NC-20 depending on size.

Loudspeaker Measurement per IEC 60268-5

Walk-in compact chambers (1.5–2 m test distance) meet the minimum test distance and background noise requirements for IEC 60268-5 loudspeaker frequency response measurement. Microphone stand mount points are included on the ceiling and two side walls. Optional turntable base for polar measurement.

Fast Delivery and Installation

Modular panel construction ships flat in standard freight. Tabletop and benchtop enclosures are delivered pre-assembled. Walk-in chambers assemble in 2–5 days on site with no structural work required. Tabletop models are plug-and-play with a single power connection. All models include a calibration report and operating guide.

准备讨论您的需求了吗?

发送设备图纸、现场照片、目标噪声值和文件要求,我们将进行评估。

获取免费报价 →