技术规格
规格仅用于初步项目评估。最终参数、材料、证书和验收标准应以签署合同或批准的技术方案为准。
应用
- End-of-line (EOL) acoustic QC testing
- Household appliance noise measurement
- Power tool production testing
- Electric motor acoustic signature analysis
- HVAC unit noise certification
- R&D product development testing
概览
An acoustic test room serves a dual function: the outer shell attenuates external noise to create a low-background measurement environment, while the interior treatment controls reverberation to provide a diffuse or semi-diffuse field for repeatable production testing.
HEMU Acoustics acoustic test rooms are designed for end-of-line (EOL) production quality testing, where each manufactured product must pass a noise signature check before dispatch. The room provides consistent acoustic conditions shift-to-shift and line-to-line, enabling statistical process control for acoustic quality.
Background noise levels of NC-25 or lower are achievable, ensuring that even quiet products (< 40 dB(A)) can be measured with adequate signal-to-noise ratio. Reverberation time (T60) is tuned to the measurement standard — typically 0.4–0.8 s for ISO 3744 sound power determination, or 0.1–0.2 s for directional microphone measurements.
Automated test station provisions — including fixture mounting points, cable pass-throughs, robot arm access hatches, and PLC I/O connections — are integrated into the room design for seamless production line integration. Optional conveyor integration allows products to enter and exit the room on the production line without manual handling.
核心特性
Production Line Integration
Conveyor pass-through hatches with acoustic seals. Robot arm access ports. PLC I/O and Ethernet connections for automated test sequencing.
Tuned Reverberation
Interior absorption designed to achieve target T60 for the specific measurement standard. Variable absorption panels available for multipurpose rooms.
Low Background Noise
Double-wall outer shell with spring-isolated inner structure. Silenced ventilation achieving NC-25 or better under operating conditions.
Fixture Mounting System
M12 threaded inserts on floor and walls for product fixtures. 3D measurement grid mounting points in ceiling for microphone positioning.
Data Acquisition Ready
Multi-channel microphone pre-amplifier rack provisions. Cable management to external DAQ or test system. EMC shielding option.
Acoustic Qualification
Full acoustic acceptance test including background noise survey, reverberation time measurement, and diffuse-field qualification map.
项目应用案例
应用案例:声学测试室
精选应用案例用于在报价前比较产品适配、安装限制和询价输入。
准备讨论您的需求了吗?
发送设备图纸、现场照片、目标噪声值和文件要求,我们将进行评估。