Free-Field Acoustic Environment
완전 무향실
Complete 6-wall wedge absorption system providing a true free-field acoustic environment above the design cut-off frequency. Engineered for transducer calibration, audio product certification, and precision NVH measurement.
제품 갤러리
사진 5장 · 클릭하여 확대기술 사양
사양은 예비 프로젝트 검토용입니다. 최종 매개변수, 자재, 인증서 및 승인 기준은 서명된 계약서 또는 승인된 기술 제안서에서 확인해야 합니다.
적용 분야
- Loudspeaker & transducer measurement
- Microphone calibration (IEC 61094)
- Headphone & hearing aid testing
- Automotive NVH component testing
- Consumer electronics certification
- Acoustic research & development
개요
A fully anechoic chamber eliminates all acoustic reflections through wedge-shaped absorbers installed on all six surfaces — walls, ceiling, and floor. The result is a free-field environment where sound propagates outward without boundaries, replicating an infinitely large outdoor space within a controlled laboratory setting.
HEMU Acoustics fully anechoic chambers are designed to achieve free-field conditions above the specified cut-off frequency (typically 80–100 Hz), with NRC values of 0.99 or higher. Our modular construction system enables chambers ranging from compact 5 m³ units for microphone calibration to large-scale 500+ m³ facilities for automotive component testing.
All chambers include an internal suspended wire floor grid for safe access, double-leaf wall construction for structural isolation, and an electromagnetic shielding option for EMC-sensitive applications.
Common applications include loudspeaker directivity measurements, headphone and microphone calibration, hearing aid testing, automotive component NVH characterization, and certification testing to IEC 60268-5, ISO 26101, and related standards.
주요 특징
Superior Free-Field Accuracy
Designed to meet or exceed the free-field deviation criterion of ±1.5 dB across the working area, ensuring measurement repeatability.
Modular Construction
Factory-prefabricated panels for fast on-site assembly. Standard modular units ship in 6–8 weeks; custom projects in 12–16 weeks.
Structural Vibration Isolation
Inner shell isolated from outer shell via spring mounts, achieving >40 dB insertion loss against floor-borne vibration.
Access & Safety
Suspended wire mesh floor grid rated to 250 kg/m². Emergency lighting, ventilation, and intercom included as standard.
Custom Absorber Design
Wedge geometry optimized via FEM simulation for your target cut-off frequency. Fiberglass, melamine foam, or hybrid wedge options.
Compliance Documentation
Full acoustic acceptance test report provided. Data includes insertion loss, background noise level, and free-field qualification map.
Project application cases
Application cases for 완전 무향실
Selected application examples help compare product fit, installation constraints, and inquiry inputs before quotation.

Anechoic & Acoustic Test Chambers
Fully Anechoic Chamber Application Case for Fully Anechoic Chamber



Application review and configuration reference for project planning.
Read case study
Anechoic & Acoustic Test Chambers
Anechoic Chamber Price Application Case for Fully Anechoic Chamber



Application review and configuration reference for project planning.
Read case study
Anechoic & Acoustic Test Chambers
Anechoic Chamber For Sale Application Case for Fully Anechoic Chamber



Application review and configuration reference for project planning.
Read case study요구사항을 논의할 준비가 되셨나요?
검토를 위해 장비 도면, 현장 사진, 목표 소음 수준 및 문서 요구사항을 보내주세요.